Achieve precise silver halide photography results with Hydroxylamine Hydrochloride CAS 5470-11-1, a high-purity solution additive that ensures consistent image development. This white powder, engineered with a bulk density of 900kg/M³, dissolves easily at 560g/L (20°C) to create reliable processing solutions—no guesswork about material quality here.
- Maintains stable pH levels (2.5-3.5 at 25°C) for controlled chemical reactions, critical for professional-grade photography
- Packaged in 1kg bags or 25kg drums (with custom options available) to suit both small studios and large production needs
- Hygroscopic formulation requires proper storage, ensuring long-term effectiveness for your workflow
Trust a supplier focused on delivering consistent, industry-specific materials—your photography solutions deserve nothing less.
Description
For industrial manufacturing and laboratory research purposes only.
Product Specifications
| Parameter | Value |
|---|---|
| Product Name | Hydroxylamine Hydrochloride |
| CAS Number | 5470-11-1 |
| Type | Synthesis Material Intermediates |
| Appearance | Powder |
| Quality Grade | Industrial |
| Colour | White |
| Bulk Density | 900kg/M³ |
| pH Value | 2.5-3.5 (25ºC, 50mg/Ml in H₂O) |
| Water Solubility | 560 G/L (20 ºC) |
| Sensibility | Hygroscopic |
| Transport Package | 1kg Bag, 25kg Drum |
| Specification | provide tailored package on request |
| Origin | China |
Hydroxylamine Hydrochloride CAS 5470-11-1: Overcoming Photography Solution Instability
After a decade serving photographic chemical manufacturers, we’ve witnessed how inconsistent Hydroxylamine Hydrochloride quality sabotages silver halide emulsion stability—batch variations causing development time fluctuations, and hygroscopic impurities ruining solution shelf life. Researchers repeatedly report failed replications due to unstandardized raw materials, while production lines face costly downtime from supply chain disruptions.
A Stable Foundation for Photography Solutions
Our Hydroxylamine Hydrochloride delivers the consistency your silver halide photography solutions demand. With 10+ years optimizing synthesis processes for industrial clients across 50+ countries, we’ve honed production to ensure each 900kg/M³ bulk density batch meets identical specifications, eliminating the guesswork from your formulation process.
Industrial Applications Beyond Photography
While widely recognized for silver halide photography solutions, this white hydroxylamine hydrochloride powder serves as a critical intermediate in organic synthesis, reducing agents production, and pharmaceutical R&D. Its high water solubility (560 G/L at 20ºC) and controlled pH make it invaluable for controlled chemical reactions in laboratory settings and industrial manufacturing.
Key Specifications That Drive Performance
The 900kg/M³ bulk density ensures efficient packaging and handling, minimizing transport costs while maximizing storage space utilization. Its hygroscopic nature necessitates our specialized packaging, which maintains stability during transit—a critical factor for maintaining solution integrity upon arrival. The precise pH range (2.5-3.5) prevents unwanted side reactions in sensitive photographic emulsions, while industrial-grade purity guarantees minimal interference in analytical applications.
Risk Mitigation Through Quality Assurance
Choosing substandard hydroxylamine hydrochloride exposes operations to multiple risks: unpredictable reaction outcomes, increased waste from failed batches, and potential compliance issues with industrial safety standards. Our rigorous production controls align with ISO9001 guidelines, ensuring each shipment meets consistent quality benchmarks. The reliability of our supply chain translates to predictable production schedules and reduced operational disruptions for your business.
Our Commitment to Quality Control
Every batch undergoes comprehensive testing including solubility verification, pH measurement, and appearance assessment. We provide a complete Certificate of Analysis with each delivery, documenting key parameters to validate compliance with your specifications. Our production facility maintains 500-ton annual capacity, ensuring stable supply even for large-scale manufacturing requirements. Dedicated technical support staff are available to address application-specific questions, drawing on our extensive experience serving industrial and research clients.
Certificate of Analysis & Documentation
Each shipment includes a batch-specific Certificate of Analysis detailing all tested parameters and compliance results. Material Safety Data Sheets (MSDS) are provided in multiple languages to support global regulatory requirements. For critical applications, additional testing data can be requested prior to order confirmation, ensuring full transparency before procurement.
Storage & Handling
- Store in a cool, dry, well-ventilated area, sealed and away from direct sunlight.
- Keep away from incompatible materials, food and feed sources.
- Handle with appropriate personal protective equipment (gloves, goggles, lab coat).
- Follow good industrial hygiene practices. Avoid inhalation and skin contact.
- Refer to MSDS for detailed storage and safety instructions.
Streamlined Procurement Process
Initiate your order by requesting technical specifications or samples for evaluation. Our team will confirm packaging options and lead times based on your requirements. Once specifications are approved, we arrange secure delivery with full documentation. Regular clients benefit from dedicated account management to streamline repeat orders and ensure consistent supply.
Frequently Asked Questions
Q: What is the shelf life of Hydroxylamine Hydrochloride when properly stored?
A: When stored in original sealed packaging under recommended conditions, the product maintains stability for 12 months from the manufacturing date.
Q: Is this product suitable for food or pharmaceutical applications?
A: No, this product is intended for industrial and laboratory research use only, not for direct human consumption or therapeutic applications.
Q: What documentation is provided with each shipment?
A: Each delivery includes a Certificate of Analysis (COA) and Material Safety Data Sheet (MSDS) specific to the batch.
Q: Can you accommodate custom packaging requirements?
A: Yes, tailored packaging solutions are available upon request to meet specific handling or storage needs.
Q: How is product purity verified?
A: Purity is assessed through multiple parameters including solubility testing, pH measurement, and visual inspection as part of our standard quality control protocol.







